Structural & Mechanical Calculators

ISO 1328 Flank Tolerances

Cylindrical spur and helical gears to ISO 1328-1:2013. Results are rounded the way the standard requires for a drawing or inspection sheet.

Updated

Gear data

mm
deg
mm

Leave blank to use the nearest integer of z/8.

µm

Optional. Used only for the tooth-to-tooth single-flank band.

Key tolerances

Reference diameter d
—
Single pitch fpT
—
Cumulative pitch FpT
—
Profile total FαT
—
Helix total FβT
—
Runout FrT
—

Values in the pitch, profile, and helix boxes are micrometres. Profile and helix slope, in the table below, are ± tolerances.

About this calculator

ISO 1328-1:2013 is the flank tolerance classification for individual cylindrical involute gears. A single class, from 1 (tightest) to 11, sets the allowable pitch, profile, and helix deviations. The reference diameter is calculated from the normal module, tooth count, and helix angle:

d = mn z / cos β

Adjacent classes differ by √2. The class 5 value is calculated first, then multiplied by 20.5(A−5). Each reported micrometre value is then rounded: nearest 0.1 µm below 5 µm, nearest 0.5 µm from 5 µm to 10 µm, and nearest 1 µm above 10 µm.

What the tolerances mean

The diagrams below are drawn for this page from the definitions in ISO 1328-1. They follow the same chart convention used in gear metrology books: an unmodified involute or helix is drawn as a straight line, and the deviation is the distance away from that line.

(a) Transverse plane d Blue dashed: reference circle (b) Face of a helical gear β b
(a) Reference diameter d is the blue dashed circle, d = mn z / cos β. (b) On the reference cylinder the teeth run at helix angle β across facewidth b. The tolerance formulas use d, mn and b.
theoretical pitch actual flank p fp Fp Measurement circle
Homologous flanks on the measurement circle. Single pitch fp is the offset of one pitch from the theoretical spacing p. Total cumulative pitch Fp is the largest algebraic build-up around the gear. A sector of k pitches is Fpk.
Profile chart — unmodified involute appears as a straight line design mean line measured (a) Total Fα Fα root tip Lα (b) Form ffα ffα root tip Lα (c) Slope fHα (±) fHα root tip Lα
ISO 1328 profile evaluation, three quantities from one trace. (a) Fα is the band of two design-profile lines that enclose the measured profile. (b) ffα is the band about the least-squares mean line. (c) fHα is the slope of that mean line relative to the design, applied as a ± tolerance.
Helix chart — an unmodified helix also appears as a straight line (a) Total Fβ Fβ face I face II Lβ (b) Form ffβ ffβ face I face II Lβ (c) Slope fHβ (±) fHβ face I face II Lβ
Helix evaluation uses the same three quantities across the facewidth. The measured trace here is slightly crowned, so form ffβ is large while slope fHβ stays small. Fβ still encloses the whole trace. Slope is a ± tolerance.
(a) Probe in two-flank contact ri Ball contacts both flanks near mid-depth (b) Runout diagram of one revolution ri r max r min Fr tooth space number The slow wave is mostly eccentricity of the datum axis.
Runout Fr is the difference between the largest and smallest radial reading ri as a ball, cylinder or anvil is seated in every tooth space. ISO 1328-1 Annex E takes FrT = 0.9 FpT.

Equations

For flank tolerance class A, with d, mn, and b in millimetres and the result in micrometres, the class step is 20.5(A−5). Profile and helix totals use the unrounded slope and form values, then the total is rounded.

fpT = (0.001 d + 0.4 mn + 5) · 20.5(A−5)
FpT = (0.002 d + 0.55 √d + 0.7 mn + 12) · 20.5(A−5)
fHαT = (0.4 mn + 0.001 d + 4) · 20.5(A−5)   (±)
ffαT = (0.55 mn + 5) · 20.5(A−5)
FαT = √(fHαT² + ffαT²)
fHβT = (0.05 √d + 0.35 √b + 4) · 20.5(A−5)   (±)
ffβT = (0.07 √d + 0.45 √b + 4) · 20.5(A−5)
FβT = √(fHβT² + ffβT²)

Runout, from the normative runout annex, is 0.9 times the unrounded cumulative pitch tolerance. Sector pitch and adjacent pitch difference are informative:

FrT = 0.9 FpT
FpkT = fpT + 4 (k/z) (0.001 d + 0.55 √d + 0.3 mn + 7) · 20.5(A−5)
fuT = √2 · fpT

If you enter a design tooth-to-tooth single-flank deviation, the informative single-flank band is that design value plus and minus (0.375 mn + 5) · 20.5(A−5). The minimum is not taken below zero. The total single-flank tolerance is the unrounded cumulative pitch tolerance plus the unrounded maximum tooth-to-tooth value.

Worked example: class 5, module 3, 30 teeth

Inputs: class 5, mn = 3 mm, z = 30, β = 0°, b = 30 mm, k = 3, and a design single-flank deviation of 10 µm. These are the values already filled in above.

  1. Reference diameter: d = 3 × 30 = 90 mm. The class step is 1.
  2. Single pitch, before rounding: 0.001×90 + 0.4×3 + 5 = 6.29 µm → 6.5 µm.
  3. Cumulative pitch: 0.002×90 + 0.55×√90 + 0.7×3 + 12 = 19.50 µm → 19 µm.
  4. Profile slope 5.29 µm → ±5.5 µm. Profile form 6.65 µm → 6.5 µm. Total √(5.29² + 6.65²) = 8.50 µm → 8.5 µm.
  5. Helix slope 6.39 µm → ±6.5 µm. Helix form 7.13 µm → 7 µm. Total 9.57 µm → 9.5 µm.
  6. Runout: 0.9 × 19.50 = 17.55 µm → 18 µm.
  7. Sector of 3 pitches → 12 µm. Adjacent pitch difference → 9 µm.
  8. Single-flank band about 10 µm: minimum 3.9 µm, maximum 16 µm, total 36 µm.

Assumptions and limitations

  • One flank tolerance class is applied to every parameter. The standard allows a different class on each parameter.
  • External cylindrical gears. The reference diameter of an internal gear uses the same magnitude.
  • Combined tolerances are built from the unrounded components, then rounded once.
  • Sector pitch, adjacent pitch difference, and single-flank results are informative. Use them when the specification calls for them.
  • This page does not cover double-flank radial composite tolerances, which are in ISO 1328-2.
  • Always confirm the numerical limits on the gear drawing against the standard you have specified.

Frequently asked questions

Which edition of ISO 1328 is this?

ISO 1328-1:2013. Classes run from 1 to 11, and the formulas use the actual module, diameter, and facewidth. The 1995 edition, with its range tables and different formulas, has been withdrawn.

Why is the slope shown with a plus-minus sign?

The standard applies profile slope and helix slope as bilateral tolerances. ±5.5 µm allows a slope deviation from −5.5 µm to +5.5 µm. The other tolerances are magnitudes without a sign.

Do I have to inspect every value in the table?

No. Single pitch, cumulative pitch, profile, and helix are the normative flank tolerances. Runout is used when agreed. Sector pitch, adjacent pitch difference, and single-flank composite testing are informative.

What does a blank sector-pitch field do?

It uses k equal to the nearest integer of z/8, which is the usual sector in the standard for gears with 12 or more teeth. Enter a smaller k when the specification asks for a shorter sector.